|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
file: TFS110R.doc version 1.2 30.11.00 VI TELEFILTER Measurement condition Ambient temperature: Input power level: Terminating impedances for input: for output: 23C 0 dBm 2,9 k || -6.2 pF 2,8 k || -5.5 pF Filter specification TFS 110R 1/5 Characteristics Remark: Reference level for the relative attenuation arel of the TFS 110 R is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The reference frequency fc is the arithmetic mean value of the upper and lower frequencies at the 30 dB filter attenuation level relative to the insertion loss ae. Data Insertion loss (reference level) Reference frequency ae = amin typ. value 8 dB tolerance / limit max. 10 dB fc (30 dB-BW) 110,0 MHz 60 Gaussian kHz - Pass band shape (3 dB-BW) 3 dB 10 dB 20 dB 30 dB 40 dB bandwidth bandwidth bandwidth bandwidth bandwidth BW 965 1695 2255 2600 2840 kHz kHz kHz kHz kHz - arel Relative attenuation fc + 475 kHz fc - 425 kHz fc 800 kHz fc + 1200 kHz fc - 1210 kHz fc + 1375 kHz fc - 1395 kHz fc + 1500 kHz ... fc + 5 MHz fc + 5 MHz ... fc +10 MHz fc - 1535 kHz ... fc - 10 MHz > 40 > 40 > 45 dB dB dB max. max. min. min. min. min. min. min. min. min. 3 3 10 20 20 30 30 35 30 40 dB dB dB dB dB dB dB dB dB dB Group delay Ripple fc 576 kHz Temperature coefficient GD 250 TC 2nd order *) ns max. 400 - ns - 0,032 ppm/K t.b.d. Frequency inversion temperature To Operating temperature range Storage temperature range Input power level *) - f (Hz) = TC (ppm/K) x (T - To) x FTo (MHz) - 10 C ... + 60 C - 40 C ... + 85 C max. + 10 dBm Generated: Checked / approved: VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784- 0/ Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. file: TFS110R.doc version 1.2 30.11.00 VI TELEFILTER Construction and pin connection (All dimensions in mm) Filter specification TFS 110R 2/5 S 110 R M47 Datecode 1 2 3 4 5 6 7 8 9 10 11 12 Datecode: K L M N ... Ground Ground Output RF Return Output Ground Ground Ground Ground Input RF Return Input Ground Ground Year+week 1998 1999 2000 2001 50 test circuit L1 10 Input 50 Ohm C1 4 L2 SAW C2 Input 50 Ohm 1,2,3,5,6,7, 8,9,11,12 VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784- 0/ Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. file: TFS110R.doc version 1.2 30.11.00 VI TELEFILTER Filter specification TFS 110R 3/5 Stability Characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 2. Vibration: 3. Damp heat: (cycle) 4. Resistance to solder heat (reflow): 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 25 C to 55C / 95% r.H. / 10 cycles DIN IEC 68 - 2 - 30 Db max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing: Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: Real of empty components at start: Real of empty components at start including leader: Trailer 3000 min 300 mm min 500 mm min 300 mm Tape (all dimensions in mm) W Po Do E F : : : : : 16 4 1,5 0,3 0,1 + 0,5 EMBOSSED CARRIER TAPE Do Po P2 1,75 0,1 7,5 0,1 0,6 2 0,1 8 0,1 1,5 5,5 7,5 0,1 0,1 COVER TAPE Ct Bo E Ao F W G (min) : P2 : P1 : D1(min) : Ao : Bo Ct : : D1 G P1 13,5+/-0,1 W2 Reel (all dimensions in mm): A W1 W2 (max) : N (min) C : : : 0,2 : 330 16,4 +2 22,4 50 C A N 13 + 0,5 W1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is readable if the sprocket holes are on the left side of the tape, i.e. pin 1 identifier is close to the sprocket holes. VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784- 0/ Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. file: TFS110R.doc version 1.2 30.11.00 VI TELEFILTER Air reflow temperature conditions Filter specification TFS 110R 4/5 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C Chip-mount air reflow profile 260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240 Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784- 0/ Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. file: TFS110R.doc version 1.2 30.11.00 VI TELEFILTER History Version 1.2. Reason of Changes - tape and reel dimensions corrected Filter specification TFS 110R 5/5 Name Steiner Date 30.11.00 VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784- 0/ Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. |
Price & Availability of TFS110R |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |